F6.30.XX
Αισθητήρες Ροής Εισερχόμενου Στελέχους (Με Ρότορα)
Paddlewheel Flow Transmitter
FLS F6.30 is a
blind transmitter based on
paddlewheel. It can be applied
for the measurement of every
kind of solid-free liquids. The
F6.30 can provides different
output options using a 4-20
mA and a Solid State Relay.
Analog output can be used for
long distance transmission and
SSR can be set as an alarm or
as a volumetric pulse output.
F6.30 Paddlewheel Flow
Transmitter is provided with an
USB interface and a dedicated
software (freely downloadable
from FLS web site) which
allows to easily calibrate
instrument and to intuitively set
outputs by a PC.
The specific design allows an
accurate flow measurement
over a wide dynamic range in
pipe sizes from DN15 (0.5β) to
DN600 (24β).
Κωδικός προϊόντος | Version | Power supply | Lenght | Main Wetted Materials | Enclosure | Flow Rate Range | Weight (gr.) |
---|---|---|---|---|---|---|---|
F6.50.01 | Hall | 12 - 24 VCC | L0 | C-PVC $ EPDM | IP65 | From 0,15 to 8 m/s* | 750 |
F6.50.02 | Hall | 12 - 24 VCC | L0 | C-PVC $ FKM | IP65 | From 0,15 to 8 m/s* | 750 |
F6.50.03 | Hall | 12 - 24 VCC | L1 | C-PVC $ EPDM | IP65 | From 0,15 to 8 m/s* | 800 |
F6.50.04 | Hall | 12 - 24 VCC | L1 | C-PVC $ FKM | IP65 | From 0,15 to 8 m/s* | 800 |
F6.50.05 | Hall | 12 - 24 VCC | L0 | PVDF $ EPDM | IP65 | From 0,15 to 8 m/s* | 750 |
F6.50.06 | Hall | 12 - 24 VCC | L0 | PVDF $ FKM | IP65 | From 0,15 to 8 m/s* | 750 |
F6.50.07 | Hall | 12 - 24 VCC | L1 | PVDF $ EPDM | IP65 | From 0,15 to 8 m/s* | 800 |
F6.50.08 | Hall | 12 - 24 VCC | L1 | PVDF $ FKM | IP65 | From 0,15 to 8 m/s* | 800 |
F6.50.09 | Hall | 12 - 24 VCC | L0 | 316L SS $ EPDM | IP65 | From 0,15 to 8 m/s* | 950 |
F6.50.10 | Hall | 12 - 24 VCC | L0 | 316L SS $ FKM | IP65 | From 0,15 to 8 m/s* | 950 |
F6.50.11 | Hall | 12 - 24 VCC | L1 | 316L SS $ EPDM | IP65 | From 0,15 to 8 m/s* | 1000 |
F6.50.12 | Hall | 12 - 24 VCC | L1 | 316L SS $ FKM | IP65 | From 0,15 to 8 m/s* | 1000 |
- APPLICATIONS βʼ Industrial water and wastewater treatment βʼ Cooling water systems βʼ Swimming pools βʼ Flow control and monitoring βʼ Water treatment βʼ Water regeneration plant βʼ Processing and manufacturing industry βʼ Water distribution MAIN FEATURES βʼ High chemical resistance βʼ Pipe size range: from DN15 (0,5β) to DN600 (24β) βʼ Low pressure drop βʼ Friendly calibration procedure βʼ 4-20 mA, frequency or volumetric pulse output settable by USB βʼ SSR settable as alarm by laptop