UB SDR 11

Coupler without inner stop, SDR 11

Coupler UB SDR 11 without inner stop

  • Gas, water and H2
  • Maximum pressure: Gas 10 bar, Water 16 bar
  • Material: PE 100
  • Safety technology
  • Large insertion depth for good pipe routing (no holding devices required)
  • DVGW test mark: DV-8601AU2248, DV-8606AU2249, DV-8611AU2250 and DW-8610CN04200
  • FM Approvals Class: 1613 (d 63 - d 500)

Note:

From nominal size 400 with separate fusion zone and preheating technology.

Go back Data sheet

PE 100 SDR 11

Maximum permissible working pressure 16 bar (water) / 10 bar (gas)

Reference d BX PU D L t h B Weight kg
616577 16 135 4320 29 60 30 16 45 0,030
612662 32 60 1920 45 77 39 21 61 0,064
612663 40 40 1280 54 86 43 23 71 0,096
612664 50 25 800 68 98 49 27 82 0,151
612665 63 15 480 82 112 56 29 96 0,225
612666 75 50 400 98 122 61 32 110 0,360
612667 90 30 240 114 157 78 51 127 0,510
612668 110 24 192 137 159 79 49 152 0,705
612669 125 16 128 156 172 86 46 169 0,946
615001 140 12 96 174 184 92 52 185 1,270
612671 160 8 64 199 190 95 52 207 1,772
612672 180 6 48 220 210 105 63 228 2,088
612673 200 1 56 247 220 110 63 252 2,798
612674 225 1 36 277 236 118 57 280 3,930
617278 250 1 24 309 247 123,5 66 309 5,418
617279 280 1 18 344 269 134,5 66 344 7,068
1 612670 315 1 18 390 300 150 78 390 10,040
2 615074 355 1 9 445 300 150 68 445 14,600
615075 400 1 4 500 320 160 90 500 22,250
615076 450 1 4 560 340 170 79 560 29,100
615124 500 1 2 630 360 180 80 630 40,000
616312 560 1 2 715 380 190 95 715 55,000
616269 630 1 2 810 420 210 101 810 79,600
616313 710 1 1 900 442 210 108 900 101,000
616314 800 1 1 1000 500 250 136 1000 138,800
616440 900 1 1 1130 600 300 165 1130 210,300
616989 1000 1 1 1200 680 340 171 1200 223,600
1 new design up to Q4/2023
2 new design up to Q2/2024

Please note the mandatory labels directly on the product. DVGW test marks issued: DV-8601AU2248, DV-8606AU2249 and DV-8611AU22500.

Areas of Application

The FRIALEN-Coupler UB is used for cut and lay pipe connections.

Additional areas of application:

  • Integration of adapters into an existing pipeline
  • Connection of pipelines with fixed or restraint points
  • Reinforcement / sealing of localised pipe damage
  • Reinforcement of pinch points on small dimensions

Assembly Instructions

The fusion of pipe ends with the FRIALEN-Coupler UB takes place using FRIALEN-fusing – leakproof and longitudinally strong.

The pipe ends are prepared according to the general installation instructions (see “Assembly Instructions” for “FRIALEN-Safety Fittings for house connections and distribution pipes up to d 225” and “FRIALEN-Special Technology for laying large bore pipes and relining pipe networks”). This involves removing the oxide skin and cleaning the pipe ends. Please note that spigot of valves must be at least half as long as the coupler.

To compensate a larger annular gap (> 1 mm, max. 3 mm) between coupler and pipe, the pre-heating barcode can be used for couplers UB from d 400 (see instructions packed up with the coupler).

For removal of the oxide layer, FWSG scraper tools are available which facilitate a uniform swarf removal and a reproducible quality of the fusion area preparation.

Good reasons for using the FRIALEN-Slide-over Coupler UB:

  • Large coupler depth for ease of pipe guiding (no holding clamps required)
  • Extra wide fusion zones
  • Maximum stability through great wall thickness
  • Cold zones at the front side and in the middle of the coupler
  • Exposed heating coil for direct heat transmission to the pipe
  • Small annular gap for build-up of optimum joining pressure in the fusion zone
  • Touch proof electric contacts
  • Fusion indicators for visual fusion control
  • From d 400: pre-heating technique for a optimal gapbridging
  • From d 400: External reinforcement for an ideal fusion pressure
  • Durable batch marking
  • Individually wrapped for dirt protection
  • Additional barcode for tracing back the fitting (Traceability-Coding).