DAP

Horizontal tapping tee, SDR 11

Horizontal tapping tee DAP SDR 11

  • Gas and water
  • Working pressure: MOP (gas) 10 bar, PFA (water) 16 bar
  • Material: PE 100
  • Conventional clamping technology (brackets and screws)
  • Vertical outlet for special solutions:
    • Space-saving installation
    • With 90 degree elbow and ball valve = Rotatable dome 360 degrees
  • Leak test possible before drilling.
  • Integrated drill with upper and lower inner stop
  • Sealing plug with internal sealing O-ring
  • Safety technology
  • DVGW test mark: DV-8601AU2248 and DV-8606AU2249

Note:

Utilise the operating key FWSS SW 17 for d 63 (Order No. 613246) or FWSS SW 19 from d 90 (Order No. 613250).

There is a suitable pressure test adapter FWDPA for DAP (Order No. 613595).

Go back Data sheet

Areas of Application

The FRIALEN DAP is used for HD-PE pipe systems both in the water and gas industry. The outlet spigot has been designed to be extra long. These pressure tapping tees are particularly suited for space-saving horizontal installation.

Assembly Instructions

The fusion of the HD-PE distribution pipes and the house connections with FRIALEN-Pressure Tapping Tees takes place by FRIALEN-fusing –leakproof and longitudinally strong.

The saddle and the outlet spigot have to be prepared according to the general installation instructions (see “Assembly Instructions” for “FRIALEN-Safety Fittings for house connections and distribution pipes up to d 225”). This involves removing the oxide skin and cleaning the pipe covered by the saddle.

Good reasons for using FRIALEN DAP Pressure Tapping Tees:

  • Economy due to space-saving horizontal installation. Excavation depth of pipe system trenches reduced by 10-20 cm

  • Protection from damage during subsequent work in the trench through the dome and outlet being positioned below the mains pipe apex

  • Length of the outlet spigot measured for 2 fusions

  • Additional barcode for tracing back the underground fitting (Traceability-Coding)

In addition, all tried-and-tested advantages of a FRIALEN Pressure Tapping Tee apply:

  • Drill guidance through metallic threaded coupling

  • No gas escapes during drilling process

  • Little force required for drilling

  • Secure position of the cut-out calotte in the drill

  • Upper and lower end position

  • Broad fusion zone

  • Valve dome can be fused with the seal cap after drilling

  • No shavings on drilling

  • Possible to carry out leakage check before drilling