With extra long outlet spigot
T-piece TA SDR 11 with spigot
- Gas, water and H2
- Working pressure: MOP (gas) 10 bar, PFA (water) 16 bar
- Material: PE 100
- Spigot
- Safety technology
- DVGW test mark: DV-8601AU2248 and DV-8606AU2249
With extra long outlet spigot

Reference | d | BX | PU | D | L1 | t | t1 | z | h | B | Weight [kg] |
---|---|---|---|---|---|---|---|---|---|---|---|
616685 | 20/20 | 200 | 3200 | 29 | 95 | 31 | 45 | 8 | 17 | 42 | 0,040 |
616338 | 25/25 | 50 | 900 | 36 | 110 | 41 | 66 | 13 | 19 | 54 | 0,080 |
615719 | 32/32 | 35 | 630 | 44 | 131 | 39 | 80 | 19 | 22 | 61 | 0,120 |
615720 | 40/40 | 20 | 360 | 53 | 151 | 43 | 88 | 30 | 25 | 70 | 0,210 |
615721 | 50/50 | 10 | 180 | 67 | 186 | 49 | 110 | 38 | 29 | 80 | 0,360 |
615722 | 63/63 | 10 | 180 | 81 | 203 | 56 | 125 | 42 | 33 | 94 | 0,530 |
FRIALEN safety fittings can be fused with SDR11 - SDR17.6 pipes.
Minimum wall thickness s minimum ≥ 3 mm.
Other levels of SDR can be processed on request.
Please note the mandatory labels directly on the product.
DVGW test mark issued: DV-8601AU2248 and DV-8606AU2249.
Dimension B = Diameter D with contact pin
Areas of Application
The FRIALEN-T pieces TA are used for pipe outlets of HD-PE pipelines.
Assembly Instructions
The fusion of the pipe ends with the FRIALEN-TA takes place by FRIALEN-fusing – leakproof and longitudinally strong.
The pipe ends are prepared (removing the oxide layer/cleaning) according to the general installation instructions (see “Assembly Instructions” for “FRIALEN-Safety Fittings for house connections and distribution pipes up to d 225”).
Good reasons for using the FRIALEN-TA:
- Large coupler depth for ease of pipe guiding (no holding clamps required)
- At dim. up to d 63, Length of outlet spigot dimensioned for two fusion operations
- Extra wide fusion zones
- Maximum stability through great wall thickness
- Cold zones at the front side and in the middle of the coupler
- Exposed heating coil for direct heat transmission to the pipe
- Small annular gap for build-up of optimum joining pressure in the fusion zone
- Touch proof electric contacts
- Durable batch marking
- Individually wrapped for dirt protection
- Additional barcode for tracing back the fitting (Traceability-Coding)