With standard outlet spigots
T-piece TA SDR 11 with spigot
- Gas, water and H2
- Working pressure: MOP (gas) 10 bar, PFA (water) 16 bar
- Material: PE 100
- Spigot
- Safety technology
- DVGW test mark: DV-8601AU2248 and DV-8606AU2249
With standard outlet spigots

Reference | d | BX | PU | D | L1 | t | t1 | z | h | B | Weight [kg] | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
616677 | 90/90 | 12 | 96 | 116 | 219 | 79 | 79 | 61 | 43 | 126 | 1,250 | |
616680 | 110/110 | 6 | 48 | 141 | 247 | 82 | 82 | 73 | 48 | 148 | 1,950 | |
616684 | 160/160 | 3 | 24 | 203 | 326 | 98 | 98 | 97 | 45 | 205 | 4,950 | |
1 | 617175 | 180/180 | 2 | 16 | 223 | 389 | 105 | 87 | 143 | 49,9 | 228 | 8,120 |
1 | 617179 | 200/200 | 1 | 8 | 247 | 425 | 112 | 112 | 158 | 50,3 | 250 | 10,720 |
1 | 617183 | 225/225 | 1 | 6 | 278 | 469 | 120 | 120 | 175 | 61,2 | 281 | 15,050 |
FRIALEN safety fittings can be fused with SDR11 - SDR17.6 pipes.
Minimum wall thickness s minimum ≥ 3 mm.
Other levels of SDR can be processed on request.
Please note the mandatory labels directly on the product.
DVGW test mark issued: DV-8601AU2248 and DV-8606AU2249.
Dimension B = Diameter D with contact pin
Areas of Application
The FRIALEN-T pieces TA are used for pipe outlets of HD-PE pipelines.
Assembly Instructions
The fusion of the pipe ends with the FRIALEN-TA takes place by FRIALEN-fusing – leakproof and longitudinally strong.
The pipe ends are prepared (removing the oxide layer/cleaning) according to the general installation instructions (see “Assembly Instructions” for “FRIALEN-Safety Fittings for house connections and distribution pipes up to d 225”).
Good reasons for using the FRIALEN-TA:
- Large coupler depth for ease of pipe guiding (no holding clamps required)
- At dim. up to d 63, Length of outlet spigot dimensioned for two fusion operations
- Extra wide fusion zones
- Maximum stability through great wall thickness
- Cold zones at the front side and in the middle of the coupler
- Exposed heating coil for direct heat transmission to the pipe
- Small annular gap for build-up of optimum joining pressure in the fusion zone
- Touch proof electric contacts
- Durable batch marking
- Individually wrapped for dirt protection
- Additional barcode for tracing back the fitting (Traceability-Coding)