TA RED SDR 11

With standard outlet spigots

T-piece TA RED SDR 11 with reduced spigot

  • Gas, water and H2
  • Working pressure: MOP (gas) 10 bar, PFA (water) 16 bar
  • Material: PE 100
  • Reduced spigots
  • Safety technology
  • DVGW test mark: DV-8601AU2248, DV-8606AU2249 and DV-8611AU2250
Go back Data sheet

With standard outlet spigots

Reference d1 d2 BX PU D L1 t t1 z h B Weight [kg]
616675 90 32 10 80 116 172 79 44 61 43 126 1,050
616676 90 63 10 80 116 191 79 63 61 43 126 1,100
616678 110 63 8 64 141 216 82 63 73 48 148 1,700
616679 110 90 8 64 141 244 82 79 73 48 148 1,850
616681 160 90 3 24 203 305 98 79 97 45 205 4,400
616682 160 110 3 24 203 308 98 82 97 45 205 4,500
616683 160 125 3 24 203 313 98 87 97 45 205 4,600
617174 180 125 2 16 223 357 105 87 143 49,9 228 7,160
1 617176 200 90 1 8 247 360 112 79 158 50,3 250 8,410
1 617177 200 110 1 8 247 370 112 82 158 50,3 250 8,890
1 617178 200 160 1 8 247 401 112 98 158 50,3 250 9,900
1 617180 225 90 1 8 278 389 120 79 175 61,2 281 11,550
1 617181 225 110 1 8 278 399 120 82 175 61,2 281 12,200
1 617182 225 160 1 8 278 430 120 98 175 61,2 281 13,370
616427 250 225 1 2 310 440 128 - 254 80 - 21,800
616429 280 225 1 2 350 475 139 - 312 84 - 30,800
616431 315 225 1 2 396 525 150 - 359 80 - 43,500
1 Available from Q2 / 2025

FRIALEN safety fittings can be fused with SDR11 - SDR17.6 pipes.

Minimum wall thickness s minimum ≥ 3 mm.

Other levels of SDR can be processed on request.

Please note the mandatory labels directly on the product.

DVGW test mark issued: DV-8601AU2248, DV-8606AU2249 and DV-8611AU2250.

Dimension B = Diameter D with contact pin

Areas of Application

The FRIALEN reduced TA red pieces are used for pipe outlets of HD-PE pipelines.

Assembly Instructions

The fusion of the pipe ends with the FRIALEN TA red takes place by FRIALEN-fusing – leakproof and longitudinally strong.

The pipe ends are prepared (removing the oxide layer/cleaning) according to the general installation instructions (see “Assembly Instructions” for “FRIALEN-Safety Fittings for house connections and distribution pipes up to d 225”).

Good reasons for using the FRIALEN TA red:

  • Large coupler depth for ease of pipe guiding (no holding clamps required)

  • At dim. up to d1 63, Length of outlet spigot dimensioned for two fusion operations

  • Extra wide fusion zones

  • Maximum stability through great wall thickness

  • Cold zones at the front side and in the middle of the coupler

  • Exposed heating coil for direct heat transmission to the pipe

  • Small annular gap for build-up of optimum joining pressure in the fusion zone

  • Touch proof electric contacts

  • Durable batch marking

  • Individually wrapped for dirt protection

  • Additional barcode for tracing back the fitting (Traceability-Coding)

Downloads