Pressure pipe PN25 solvent socket NF-EN 1452-2

PVC-U PN25 Pressure pipe solvent socket NF-EN 1452-2, Grey RAL 7011, length 6m.

Pressure pipes for joint system by cold chemical welding (gluing through the use of suitable WELD-ON adhesive and detergent primer) or FORSHEDA 601 POWERLOCK® pre-inserted and locked gasket joint.

Lareter rigid PVC pipes for pressure pipes are guaranteed by the certifications issued by IIP, CSTB, DVGW, WRAS and IMO.

Go back Data sheet
Disegno del tubo a pressione in PVC-U bicchierato
Reference Other description system Category family series D (mm) S (mm) Weight (kg/m) Qty x pallet Lb (mm)
PIPEV09016I6L * upon request VDA system Pipes PVC-A Pipe BS-PAS-27:1999 PN8 pipe 16 1.8 0.13 Bulk -
PIPEV09020I6L * upon request VDA system Pipes PVC-A Pipe BS-PAS-27:1999 PN8 pipe 20 2.3 0.2 1166 37
PIPEV09025I6L * upon request VDA system Pipes PVC-A Pipe BS-PAS-27:1999 PN8 pipe 25 2.8 0.30 757 40
PIPEV09032I6L * upon request VDA system Pipes PVC-A Pipe BS-PAS-27:1999 PN8 pipe 32 3.6 0.49 449 65
PIPEV09040I6L * upon request VDA system Pipes PVC-A Pipe BS-PAS-27:1999 PN8 pipe 40 4.5 0.77 275 70
PIPEV09050I6L * upon request VDA system Pipes PVC-A Pipe BS-PAS-27:1999 PN8 pipe 50 5.6* 1.19 194 85
PIPEV09063I6L * upon request VDA system Pipes PVC-A Pipe BS-PAS-27:1999 PN8 pipe 63 7.1* 1.89 123 90

* upon request

  • Size range: d 16 - d 500 (mm)
  • Nominal pressure: PN 6-10-12,5-16-20-25 with water at 20° C
  • Temperature range: 0 °C ÷ 60 °C
  • Coupling standards
    • Solvent welding: EN ISO 15493, EN ISO 1452, DIN 8061/2.
    • Coupling: Forsheda 601 POWER-LOCK® Gasket
  • Reference standards
    • Construction criteria: EN ISO 15493, EN ISO 1452, DIN 8061/2
    • Test methods and requirements: EN ISO 15493, EN ISO 1452, DIN 8061/2
    • Installation criteria: DVS 2204, DVS 2221, UNI 11242, EN ISO 1452, DIN 8061/2
  • Pipe material: PVC-U dark grey RAL 7011

Downloads

LARETER Technical Catalogues