MV SDR 11

Cap, SDR 11

Cap MV SDR 11

  • Gas, water and H2
  • Working pressure: MOP (gas) 10 bar, PFA (water) 16 bar
  • Material: PE 100
  • Safety technology
  • DVGW test mark: DV-8601AU2248 and DV-8606AU2249
  • FM Approvals Class: 1613 (d 63 - d 225)
Go back Data sheet

PE 100 SDR 11

Maximum permissible working pressure 16 bar (water) / 10 bar (gas)

Reference d BX PU D t h B Weight [kg]
612025 20 50 2500 31 41 22 46 0,040
612026 25 50 2500 35 41 22 51 0,040
612027 32 60 1920 44 44 24 61 0,060
612028 40 50 1600 55 49 28 70 0,090
612029 50 30 960 67 55 30 80 0,120
612030 63 20 640 84 63 31 96 0,210
612031 75 80 640 99 70 31 110 0,320
612032 90 16 288 118 79 40 130 0,530
612033 110 30 240 143 82 34 153 0,850
612034 125 21 168 163 87 42 168 1,180
612035 160 10 80 208 98 54 210 2,370
616183 180 6 48 224 100 46,5 225,5 2,800
616184 200 4 32 250,6 103 48 253 3,700
616185 225 4 32 279 114 48 281,6 3,950

FRIALEN safety fittings can be fused with SDR11 - SDR17.6 pipes. Other levels of SDR can be processed on request. Please note the mandatory labels directly on the product. DVGW test marks issued: DV-8601AU2248 and DV-8606AU2249

Areas of Application

The FRIALEN-End Caps MV are used to close HD-PE pipe ends.

Also recommended as fused caps (d32 and d40) for the dome of FRIALEN-Pressure Tapping Tees DAA and DAP up to d63.

Assembly Instructions

The fusion of a pipe end or the dome of a FRIALEN-Pressure Tapping Tee with the FRIALEN-End Cap MV takes place using FRIALEN-fusing – leakproof and longitudinally strong.

The fusion area is prepared according to the general installation instructions (see “Assembly Instructions” for “FRIALEN-Safety Fittings for house connections and distribution pipes up to d 225”). This involves removing the oxide skin and cleaning the pipe ends. Next to moulded fittings and accessories it is recommended to install a piece of pipe of 20 - 60 cm length, accordingly to the diameter, so that the pipeline can be continued later on.

Good reasons for using the FRIALEN-End Caps MV:

  • Large coupler depth for ease of pipe guiding (no holding clamps required)

  • Extra wide fusion zones

  • Maximum stability through great wall thickness

  • Cold zones at the front side and in the middle of the coupler

  • Exposed heating coil for direct heat transmission to the pipe

  • Small annular gap for build-up of optimum joining pressure in the fusion zone

  • Touch proof electric contacts

  • Fusion indicator for visual fusion control

  • Durable batch marking

  • Individually wrapped for dirt protection

  • Additional barcode for tracing back the fitting (Traceability-Coding)